SUFF/UFF FILTRATION SYSTEMS
CHAPTER 3: INSTALLATION AND OPERATION
3-8
3.2.2 Assembling the Filter (cont.)
Assembling Filter Units with Latching Hold-down Rings
1. Place the filter screen in the pan. Ensure it is
properly seated in the bottom recess.
2. Place one sheet of filter paper over the filter
screen.
3. Install the hold-down ring over the filter
paper. Ensure the hold-down ring is properly
seated in the bottom recess.
Note: When placing the hold-down ring over
the filter paper, use care not to tear the filter
paper when locking the ring down. Sediment
can get into the filter system through tears in
the filter paper.
Placing filter screen (pan grid) in filter pan.
Installing hold-down ring over filter paper.